D.1 Single-System Installation of an DECarray
Figure D–3 VAX 4000 DSSI Connectors
slot #2 slot #1 slot #0
Mass Storage Area
Model 200
FRONT VIEW
slot #3 slot #2 slot #1 slot #0
Mass Storage Area
Operator/
Control Panel
Fan Tray
AC
on/off
H3604
J1
J2
J3
KFQSA
Q−Bus
Connector
Description
J1, J2
J3
KFQSA − J1
DSSI Bus 1 ports (external ISEs only)
DSSI Bus 0 port (internal/external ISEs)
DSSI IN/OUT port (external RF disk ISEs)
VAX4000_family.rags
AC Input
Ground
Stud
Model 200/300
BA4xx
KFQSA
Q−Bus
J1
J1
J1
Connector
Description
J1 DSSI Bus 0 port (internal/external ISEs)
KFQSA − J1 DSSI IN/OUT port (external RF disk ISEs)
BA2xx
c. Install the terminator or terminators (part number 12–31281–01) to
their correct position on the SF7x enclosures, TF857 magazine tape
ISEs, and system I/O panel.
Note that the positions are numbered on the cabinet frame side rails
on the front and the rear of the cabinet.
If the array has an SF7x storage enclosure in position 1 ONLY then
install a terminator (12–31281–01) in the left DSSI connector of the
enclosure.
If the array has an SF7x storage enclosure in position 1 and a
TF857 magazine tape ISE in positions 5 and 6, then install a
terminator (12–31281–01) in the bottom DSSI connector of the
TF857 magazine tape ISE in position 6.
Installing a DECarray with VAX 4000 Systems D–7