8.1 Troubleshooting the SF7x Storage Enclosure
Figure 8–5 Rx7x Wedges and Skid Plate
WEDGE
SKID PLATE
SHR-X0158A-90
NOTE TO ILLUSTRATOR:
This illustration is
at .30% of original
RF72
Proceed to Section 8.1.2.
8.1.2 Bringing the Rx7x Disk ISE On-Line
This section provides the procedure for bringing all the ISEs in the SF7x
enclosure on-line and for setting DSSI ID numbers.
1. Make sure that the DSSI ID switches (behind the door on the OCP) are set
correctly. For positions 1, 2, 4, and 5, they are LR:1, RR:4, LF:2, RF:3. For
positions 3 and 6, they are LR:6, RR:6, LF:5, RF:5.
2. Place the ac power switch at the rear of the SF7x enclosure to the 1 or on
position.
3. Press all drive dc power switches.
Installation Troubleshooting 8–9