8.2 Troubleshooting the Magazine Tape Subsystem
8.2.1 Operator Control Panel Fault Indicators
The light emitting diodes (LEDs) on the operator control panel of the tape
magazine subsystem will light to indicator errors and faults as they occur in
the subsystem. These errors and faults are found in Table 8–2.
Table 8–2 Operator Control Panel Fault Indicators
LED Lit Condition
With the REJECT LED lit
Position 6 Indicates an extra cartridge present in tape ISE.
Position 5 Indicates an problem in the magazine.
With the FAULT LED lit
Position 6 Indicates an loader fault.
Position 5 Indicates an tape ISE fault.
Position 4 Indicates an controller module fault.
Should any of the above exist, refer to the magazine tape subsystem owner’s
and service manuals.
8.2.2 Fault Matrix
The fault matrix Table 8–3 describes possible scenarios associated with FRU
failures not detectable via diagnostics.
Table 8–3 Fault Matrix
Minor FRU Possible Failure Scenario
Interlock Switch After sliding the unit forward for head cleaning
or service, the Power indicator remains on.
Internal Communications Cable After replacing either a faulty ISE or subsystem
assembly, the power is on, but the unit still fails
MDM.
Handle Motor Assembly Same as above. Characterized by subsystem
retry errors.
(continued on next page)