5.2 Cabling the SF7x in Storage Array Position
1. Remove the DSSI terminator from the bottom DSSI connector on the rear
of the magazine tape subsystem in position 5.
2. Install a 42-inch DSSI cable (part number BC21Q–3F) in the bottom DSSI
connector on the rear of the magazine tape subsystem TF1.
3. Route this DSSI cable on the right side of the cabinet. Cabling the
magazine tape subsystem should make sure that the correct cable slack
will be provided.
4. Connect the 42-inch DSSI cable from the bottom DSSI connector on the
rear of the magazine tape subsystem TF1 to the rightmost DSSI connector
on the rear of the SF7x storage enclosure SF1.
Note
Perform the next step if this is the only SF7x storage enclosure to
be installed on this particular DSSI bus. If not, then proceed to the
cabling instructions for the next SF7x storage enclosure that has been
installed.
5. Install a DSSI terminator in the leftmost DSSI connector at the rear of the
SF7x.
CAUTION
Do not apply power to the SF7x storage enclosure at this time.
5.2.1.3 Cabling SF2
WARNING
Before performing the following steps, refer to the system documenta-
tion for the correct steps to perform an orderly shutdown of the system
that the Sx300 storage array is connected to.
The SF7x storage enclosure installed as SF2 of the Sx300 storage array
has two possible cabling configurations. The difference depends on
whether a magazine tape subsystem is installed (TF2) of the Sx300
storage array.
Installing the SF7x Storage Enclosure in an Sx300 Storage Array 5–21