Manx SA7x Guía de instalación Pagina 194

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 320
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 193
8.1 Troubleshooting the SF7x Storage Enclosure
4. According to the findings from the error codes and results from DUP, repair
or replace the ISE.
5. Run EVCXE configuration programs, EVCXF configuration programs, or
both.
6. Verify the repair or replacement of the ISE with DRVTST and DRVEXR
under DUP.
7. Return the system to the user.
Use Table 8–1 to isolate a failure in an SF7x storage enclosure.
Table 8–1 Troubleshooting Chart
Symptoms Probable Causes Corrective Actions
No OCP indicators are
lit.
1. SF7x enclosure is
not plugged in or
not turned on.
1. At the rear of the SF7x
enclosure, plug in the ac
power cord or turn on the
SF7x.
2. Drive dc power
switch is off.
2. At the front of the SF7x
enclosure, turn on the drive
dc power switch.
3. OCP is not plugged
in or seated firmly.
3. Press the OCP firmly in
place.
4. Bad OCP. 4. Configure and replace a new
OCP.
5. Bad TTM. 5. Configure and replace a new
TTM.
Single Fault indicator lit
on OCP.
1. Faulty Rx7x disk
ISE.
1. Press lit Fault button, then
read fault code and replace
failed FRU.
2. Conflicting DSSI ID
numbers.
2. Verify correct DSSI ID
switch settings on KFMSA
module, SF7x, and magazine
tape subsystems for that
bus.
(continued on next page)