8.2 Troubleshooting the Magazine Tape Subsystem
Poor power or grounding
Note
Make sure that any problem you encounter is not due to the above
causes before you replace the drive.
Table 8–4 Common Failures, Causes, and Fixes
Symptom Probable Cause Possible Fix
Volume not software enabled Drive is not loaded or was
unloaded by software
Make sure that the
yellow LED is on (tape
loaded and ready for
use).
TK50 formatted cartridge in
a TK70 drive
Use correct cartridge.
Bad cartridge or incorrectly
written calibration tracks
Try another cartridge.
Bad drive or dirty head Clean head and/or
replace drive.
Failure to mount or initialize
with new media
Bad media Clean head and retry
with known good
media.
All three LEDs blinking Drive failed self-test or
detected a hard error during
operation
Attempt to clear error
by pushing the unload
button. If the error
won’t clear, you have a
drive hardware failure
or a power problem.
Green LED blinking Calibration error Clear error by
pressing the unload
button. Try another
cartridge. If the error
repeats, you have
a drive hardware
failure or more than
one bad cartridge
(physically damaged
or bad calibration
tracks).
(continued on next page)
Installation Troubleshooting 8–15