5.4 Setting the Unit Number
The unit number for any drive can be set at the operator control panel. This is the number
by which the drive is known to the system. Once the number is in the drive, the system
controller reads it according to the controllers protocol.
You must take a drive off line before changing its unit number. You do not need to take any
other drives in the enclosure off line while setting a specific drive unit number, nor do you
need to spin down the selected disk to change the unit number. When the operator control
panel is in unit select mode, all drives not spun down continue to operate according to the
settings of the operator control panel switches.
To set the unit number:
1. Dismount the disk, using the proper system commands.
2. Place the desired drive off line according to the procedures in Section 5.3. Do not set the
drive power switch to Off.
3. Press the Unit Select switch with a pen or small screwdriver. The unit select numbers
for all powered-on drives in the enclosure flash to indicate that the operator control panel
is in unit select mode.
4. Press the Fault/Set No. switch once to increment the unit number by one.
Press and hold the Fault/Set No. switch to rapidly increment the unit number for that
drive. Set the unit number between 000 and 255.
Note
You cannot decrement a drive number. Holding the Fault/Set No. switch
increments to 255, then starts at 0 again.
5. Repeat that step for all drives for which you are changing numbers. If you do not press
the Fault/Set No. switch, the number remains the same as before you entered the unit
select mode.
6. After setting the unit numbers, restore the operator control panel to normal operation by
pressing the Unit Select switch again.
7. Restore the off-line drive to its on-line status. Refer to Section 5.2.
8. Remount the disk drive, using the proper system commands.
After the SA7x enclosure powers up, passes internal diagnostics, and has the unit number
set, run the SA7x/KDB50/KDM70 diagnostics to ensure the configuration is operational.