2. Route the SA7x enclosure power cord through the clamp attached to the cable manage-
ment guide as shown in Figure 3–12.
3. Plug the male end of the SA7x enclosure power cord into one of the H405–E/F power
controller outputs. Refer to Figure 3–12.
4. Install the I/O cable tie mount (90–08264–00) as shown in Figure 3–12.
5. Attach the single end of the Port A I/O cable to Port A of the SA7x enclosure.
6. Route the first SA7x enclosure’s Port A I/O cable (17–01699–02) under the SA7x en-
closure, under the power controller, and up the side of the cabinet upright to the top
KDB50/KDM70 disk controller I/O bulkhead. Refer to Figure 3–12.
7. Attach the hydra end of the Port A I/O cable to the controller I/O bulkhead, as shown
in Figure 3–12. Ends RR and LR plug into the top connectors of the controller, and the
RF and LF ends plug into the bottom connectors of the controller bulkhead. I/O cable
reference labels on each hydra end of the I/O cable further define cabling procedures.
8. Secure the I/O cable to the cable tie mount with the cable tie wrap (90–07880–00).
9. Install the two 5/8-inch cable clamps (90–07087–00) as shown in Figure 3–12, securing
the I/O cable to the cabinet upright.
Note
When installing cable clamps, remove existing 1/2-inch sems screws and replace
with 5/8-inch screws (90–00063–41) and flat washers (90–06662-00).
10. To route a second SA7x I/O cable, tie off the second I/O cable to the first I/O cable at the five
locations shown in Figure 3–13 with tie wraps (90–07880–00). Follow step 7 instructions
to route the second SA7x I/O cable to the bottom disk controller I/O bulkhead. Plug in
and route the second enclosure’s power cord as per steps 1 and 2, using an available outlet
on the H405 power controller.
3.8 Powering Up the Cabinet
To apply power to the cabinet after installation, use the following procedure:
1. Plug the cabinet power controller cord into an ac receptacle.
2. Push in the main circuit breaker T-handle located on the H405–E or –F power controller.
Refer to Figure 3–14.
3. Locate the cabinet control panel in the upper-left corner of the front door, as shown in
Figure 3–14.
4. Turn the Standby/Enable/Secure control switch to Enable.
3–20 Installing the SA70–CK Kit